I/O Hub TBIL-M1-16DXP, 16 universal digital PNP channels, IO-Link, M12
Out of stock
179.10 €

TBIL-M1-16DXP is a TURCK I/O Hub with 16 universal digital PNP channels, where each of the 8 M12 ports carries 2 channels individually configurable as input or output through the IO-Link master. Field sensors and actuators wire directly to the hub, without extra cabling back to the control cabinet.

  • Channels: 8x M12 ports, 2 universal digital channels per port (16 channels total)
  • Inputs and outputs: input max. 7 mA (-3...5 VDC / 11...30 VDC), output 24 VDC from supply, 0.5 A/channel, group diagnostics
  • Communication: IO-Link V1.1 Class A, COM2 / 38.4 kbps, 1x M12 IO-Link connection
  • Power: 24 VDC (18...30 VDC), M12 connection, max. 4 A per module
  • Housing: glass-fibre reinforced PA6-GF30, 150 x 54 x 27.4 mm
  • Environment: IP65/IP67/IP69K, -40...+70°C

Each channel's function (input or output), signal inversion and behaviour on communication loss (output 0, output 1 or last value) are set through the IO-Link master's ISDU parameters, with no separate configuration software. The hub suits mixed input/output applications, where a port's function can change without rewiring.

Complies with CE, UKCA, ATEX zone 2/22 and CCC-Ex requirements, as well as the cULus certificate (LISTED 21 W2). MTTF 96 years per SN 29500 (Ed. 99) at 20°C.

Relays and converters
In-Line converter S15C-I-KQ, analog current to IO-Link
In stock: 1 pcs
95.00 €
Compact analog current to IO-Link device converter that connects to a current source (4 mA to 20 mA) and outputs the value to the IO-Link master • Rugged over-molded design meets IP65, IP67, and IP68 • Connects directly to a sensor or anywhere in-line for ease of use
module
Multiprotocol IO-Link master module TBEN-S2-4IOL
In stock: 1 pcs
298.70 €
ATEX zone 2/22
CCC-Ex
Programmable ARGEE
module
I/O Hub TBIL-S4-8DXP, 8 universal digital PNP channels, IO-Link, M12
In stock: 1 pcs
144.50 €

TBIL-S4-8DXP is a TURCK I/O Hub in a compact housing with 8 universal digital PNP channels on 4 M12 ports, where each channel is individually configurable as input or output through the IO-Link master. Each channel has its own diagnostics, so a fault on one port does not affect the readings on the rest.

  • Channels: 4x M12 ports, 2 universal digital channels per port (8 channels total)
  • Inputs and outputs: input max. 15 mA (-3...5 VDC / 11...30 VDC), output 0.5 A/channel, channel diagnostics
  • Communication: IO-Link V1.1 Class A, COM2 / 38.4 kbps, 1x M12 IO-Link connection
  • Power: 24 VDC (18...30 VDC), M12 connection, max. 4 A system current
  • Housing: glass-fibre reinforced PA6-GF30, black, 144.3 x 32 x 32 mm
  • Environment: IP65/IP67/IP69K, -40...+70°C

The compact housing (144.3 x 32 x 32 mm) with 2 mounting holes lets the hub sit directly at a group of sensors on the machine frame, close to the field devices. Each channel's function (input or output) is set through the IO-Link master, with no separate configuration software.

Complies with CE and UKCA requirements, as well as the cULus certificate (LISTED 21 W2). MTTF 422 years per SN 29500 (Ed. 99) at 20°C.

module
I/O Hub TBIL-M1-16DIP, 16 digital PNP inputs, IO-Link, M12
Out of stock
145.90 €

TBIL-M1-16DIP is a TURCK I/O Hub that adds 16 digital PNP inputs to an IO-Link master through a single IO-Link connection. Field sensors wire directly to the hub's 8 M12 ports, and the hub reports their states to the master as one process data telegram.

  • Channels: 8x M12 sensor ports, 2 inputs per port (16 digital PNP inputs)
  • Inputs: max. 7 mA, low level -3...5 VDC, high level 11...30 VDC (EN 61131-2, type 1/3), group diagnostics
  • Communication: IO-Link V1.1 Class A, COM2 / 38.4 kbps, 1x M12 IO-Link connection
  • Power: 24 VDC (18...30 VDC), M12 connection, max. 4 A per module
  • Housing: glass-fibre reinforced PA6-GF30, 150 x 54 x 27.4 mm
  • Environment: IP65/IP67/IP69K, -40...+70°C

The hub extends an IO-Link master with additional digital inputs in a control cabinet or field junction box, without using a separate master port for each sensor. Input signal inversion is set through the IO-Link master's ISDU parameters, so no separate configuration tool is needed.

Complies with CE, UKCA, ATEX zone 2/22 and CCC-Ex requirements, as well as the cULus certificate (LISTED 21 W2). MTTF 139 years per SN 29500 (Ed. 99) at 20°C.

Level sensors
Level sensor LRS510-10-69-LI2UPN8-H1141/EU
In stock: 1 pcs
1,029.00 €
Radar Sensor, Level Control
■ Insensitive to harsh environmental conditions 
■ Distance, level and volume measurement in a single unit 
■ Simple sensor data visualization and configuration via Turck’s IO-Link masters 
■ Foreign object suppression via distance and signal intensity filter

Operating voltage 17…33 VDC, 
Max. range 10000 mm, 
Range: 10 m, 
Blind zone: 35 cm, 
Resolution: 1 mm, 
Cone angle of the radar beam: ±3°, 
Distance, level, volume or % output, 
Approved according to ETSI 305550-2, 
Approved according to FCC/CFR. 47 Part 15., 
Male connector, M12 × 1, 4-pin, 
Operating voltage 18…33 VDC, 
Switching output switchable between PNP/NPN, 
Analog output switchable between 4…20 mA/0…10 V, 
Automatic current/voltage detection, IO-Link, 4-digit, 2-colored, 14-segment display, Housing is rotatable by 180° after mounting the process connection, 
Process connection G1", 
Pressure resistance -1…16 bar rel.
Led buttons and signal towers
Touch display S100PTVD2WAKQ, IO-Link, two-row white display, Ø100 mm, 18-30VDC, IP69K, M12 4-pin
Out of stock
263.00 €

S100PTVD2WAKQ is a Banner S100 Pro series touch operator display that combines status indication, text and operator input in a single M30 threaded housing. Over IO-Link it connects to a standard master port, carrying process data and parameters on the same unshielded cable, so a replacement unit is re-parameterised by the master rather than by hand.

  • Display: two-row white dot-matrix display, 13 characters per line, 16 RGB LED ring and audible alert
  • Control: 5 capacitive touch zones with vibration feedback, response time max. 300 ms
  • Communication: IO-Link
  • Supply: 18-30 V DC, 280 mA at 18 V DC, 210 mA at 24 V DC
  • Housing: black polycarbonate with tinted window, Ø100 mm, M30x1.5 threaded base, IP66/IP69K, -40...+50°C
  • Connection: integral M12 male connector, 4-pin

The display mounts in a Ø30 mm hole at the machine station - pick-to-light positions, takt timer, counter and step confirmation. Note that this version starts at 18 V DC, not 12 V DC as the other S100 Pro versions.

CE marked and cULus listed, housing rated UL Type 4X.

Vibration
Vibration sensor CMVT-M8TA1X-LI2IOL-H1141, 10 g, 0...128 mm/s, IO-Link and 4-20mA, M8 thread, M12, IP67
Out of stock
319.00 €

CMVT-M8TA1X-LI2IOL-H1141 is a stainless steel vibration and temperature sensor with an M8 screw-in thread, measuring over one axis at a 23.6 kHz sampling rate. It is intended for rotating machine parts where rising vibration indicates bearing wear or imbalance; the sensor screws into the bearing housing along the axis where the vibration is expected.

  • Measuring range: acceleration 10 g RMS / 14 g peak, velocity 0...128 mm/s RMS @ 159 Hz, temperature -40...+80°C; resolution 0.01 g and 0.01 mm/s
  • Accuracy: ≤ ±0.5 % @ 159 Hz; temperature linearity deviation ≤ 10 %
  • Outputs: pin 4 - IO-Link or SIO, pin 2 - 4...20 mA or SIO; IO-Link COM 2 (38.4 kBaud)
  • Supply: 18...30 VDC, consumption < 120 mA in IO-Link mode
  • Housing: stainless steel, M8 screw-in thread, 72.5 x 23.8 mm
  • Environment: IP66/IP67, operating temperature -40...+80°C, shock 60 g (6 ms), vibration 20 g
  • Connection: M12 x 1 connector, 4-pin

Frequency ranges and switching thresholds are configurable over IO-Link, so only the band in which a given machine's fault appears has to be watched. The 4...20 mA output on pin 2 carries the same quantity in analogue form, so the sensor connects to a controller with no IO-Link master.

MTTF 164 years to SN 29500 (Ed. 99). Shock tested to EN 60068-2-27, vibration to EN 60068-2-6.