Skip to Content
Filters
Shop
12 items found.
Clear Filters
Baumer International
Water quality
Conductivity sensor AFI5-A813.4002.0300, 2x4-20mA, G 1" hygienic L=60mm, with display, split version, 10 m cable
Out of stock
2,553.50 €

AFI5-A813.4002.0300 is a Baumer CombiLyz inductive conductivity sensor with separate electronics: the probe with its G 1 A connection sits in the pipe, and the housing with display is wall-mounted up to 10 m away. It passes conductivity and temperature on as two separate 4...20 mA signals, and both solid-state relays in the display can be set as limit contacts.

  • Measuring range: 14 selectable ranges, 0...500 µS/cm to 0...1000 mS/cm; temperature -20...150 °C
  • Output: 2 x 4...20 mA (conductivity, temperature), 2 solid-state relays
  • Supply: 15...35 V DC
  • Housing: FlexHousing Ø80 mm, AISI 304, wall mounting, G 1 A hygienic connection, PEEK Natura probe L=60 mm
  • Environment: IP67 / IP69K; process -20...140 °C (up to 150 °C for less than 1 h), up to 25 bar
  • Connection: 2 x M16x1.5 cable glands, plastic; 10 m PUR sensor cable

Used for concentration control of CIP solutions and for phase separation between product, water and cleaning solution in dairy, brewery and beverage lines. The minimum measurable conductivity is 50 µS/cm, so the sensor does not suit demineralised or purified water. The split design keeps the electronics away from hot or hard-to-reach pipe sections.

cULus listed (E491206); wetted parts in PEEK Natura comply with FDA 21 CFR 177.2415.

Water quality
Conductivity sensor AFI4-5830.4002.0200, 2x4-20mA, G 1" hygienic L=83mm, with display, M16 glands
Out of stock
1,881.70 €

AFI4-5830.4002.0200 is a Baumer CombiLyz inductive conductivity sensor with display and bottom process connection. It passes conductivity and temperature on as two separate 4...20 mA signals, and both solid-state relays in the display can be set as limit contacts.

  • Measuring range: 14 selectable ranges, 0...500 µS/cm to 0...1000 mS/cm; temperature -20...150 °C
  • Output: 2 x 4...20 mA (conductivity, temperature), 2 solid-state relays
  • Supply: 15...35 V DC
  • Housing: FlexHousing Ø80 mm, AISI 304, G 1 A hygienic connection, PEEK Natura probe L=83 mm
  • Environment: IP67 / IP69K; process -20...140 °C (up to 150 °C for less than 1 h), up to 25 bar
  • Connection: 2 x M16x1.5 cable glands, stainless steel AISI 304

Used for concentration control of CIP solutions and for phase separation between product, water and cleaning solution in dairy, brewery and beverage lines. The minimum measurable conductivity is 50 µS/cm, so the sensor does not suit demineralised or purified water.

cULus listed (E491206); wetted parts in PEEK Natura comply with FDA 21 CFR 177.2415.

Water quality
Conductivity Sensor PAC50H-1430A.32D11A.A04304.1030, 2% accuracy, IO-Link Dual Channel and 4…20mA, M12-A, 5-pin, G 1 A hygienic, SS., With display, 37 mm probe, PEEK wetted parts, IP65/IP67/IP69K, 3-A / EHEDG approved.
Out of stock
1,420.00 €
Min. measurable conductivity
1 µS/cm
Max. measuring span
1000 mS/cm
Max. measuring error
≤ ± 2.0 % MV ± 15 µS/cm
Reference temperature
25 °C , adjustable
Repeatability
≤ ± 1.0 % MV ± 10 µS/cm
Compensated temperature range
-20 … 150 °C
Temperature compensation
0.0 … 5.0 %/K , adjustable
Step response time, T90
≤ 1.5 s
Sample time
≤ 0.4 s
Water quality
Conductivity sensor AFI4-6830.4006.1313, 2x4-20mA, IO-Link, G 1" hygienic L=60mm, with display, M16 glands
Out of stock
2,625.10 €

AFI4-6830.4006.1313 is a Baumer CombiLyz inductive conductivity sensor with display and rear process connection. It passes conductivity and temperature on as two separate 4...20 mA signals, and over IO-Link 1.1 the same readings and the sensor settings are also available digitally.

  • Measuring range: 14 selectable ranges, 0...500 µS/cm to 0...1000 mS/cm; temperature -20...150 °C
  • Output: 2 x 4...20 mA (conductivity, temperature), 2 solid-state relays, IO-Link 1.1
  • Supply: 15...35 V DC (18...30 V DC with IO-Link)
  • Housing: FlexHousing Ø80 mm, AISI 304, G 1 A hygienic connection, PEEK Natura probe L=60 mm
  • Environment: IP67 / IP69K; process -20...140 °C (up to 150 °C for less than 1 h), up to 25 bar
  • Connection: 2 x M16x1.5 cable glands, stainless steel AISI 304

Used for concentration control of CIP solutions and for phase separation between product, water and cleaning solution in dairy, brewery and beverage lines. The minimum measurable conductivity is 50 µS/cm, so the sensor does not suit demineralised or purified water.

cULus listed (E491206); wetted parts in PEEK Natura comply with FDA 21 CFR 177.2415. 3-A (74-07) and EHEDG EL Class I approved version, supplied with conductivity (5-point) and temperature (3-point) calibration certificates.

Water quality
Conductivity sensor AFI4-5D30.4006.1300, 2x4-20mA, IO-Link, G 1" hygienic L=60mm, with display, M12
In stock: 1 pcs
1,736.50 €

AFI4-5D30.4006.1300 is a Baumer CombiLyz inductive conductivity sensor with display and bottom process connection. It passes conductivity and temperature on as two separate 4...20 mA signals, and over IO-Link 1.1 the same readings and the sensor settings are also available digitally.

  • Measuring range: 14 selectable ranges, 0...500 µS/cm to 0...1000 mS/cm; temperature -20...150 °C
  • Output: 2 x 4...20 mA (conductivity, temperature), 2 solid-state relays, IO-Link 1.1
  • Supply: 15...35 V DC (18...30 V DC with IO-Link)
  • Housing: FlexHousing Ø80 mm, AISI 304, G 1 A hygienic connection, PEEK Natura probe L=60 mm
  • Environment: IP67 / IP69K; process -20...140 °C (up to 150 °C for less than 1 h), up to 25 bar
  • Connection: 1 x M12-A, 5-pin + 1 x M12-A, 8-pin, stainless steel AISI 304

Used for concentration control of CIP solutions and for phase separation between product, water and cleaning solution in dairy, brewery and beverage lines. The minimum measurable conductivity is 50 µS/cm, so the sensor does not suit demineralised or purified water.

cULus listed (E491206); wetted parts in PEEK Natura comply with FDA 21 CFR 177.2415.

Showing 12 of 12 results