Universal programmable process controller, 4 digit, analogue, 4 x relay out, 230Vac
In stock: 4 pcs
398.00 €
Display for digital readout of current / voltage / resistance / temperature or 3-wire potentiometer signals.
Individually configured input curve for lambda measurements for O2 measurements (on request).
Process control with 4 pairs of potential-free change-over relays and analog output.
For tank level control, with the possibility of customer linearization ensuring correct level measurement and control in non-linear tanks.
4-digit LED indicator with 13.8 mm 14-segment characters. Max. display readout -1999...9999 with programmable decimal point and relay ON / OFF indication.
All standard operational parameters can be adjusted to any application by way of the front function keys. When programming is carried out by way of a PC and the configuration program PReset, additional configuration options are available, such as customer-defined linearization and special input signals.
Help texts in eight languages can be selected via a menu item.
A menu item allows the user to minimize the installation test time for the relay outputs by activating / deactivating each relay independently of the input signal.
2.3 kVAC galvanic isolation between input, output and supply.
Relays and converters
Serial adapter INTUSB485-1, USB to RS-422/485, for EZ-ARRAY
Out of stock
190.00 €

INTUSB485-1 is a Banner USB to RS-422/485 adapter for configuring the EZ-ARRAY measuring light curtain from a PC with EZ-ARRAY Control Software. It is powered from the USB port and appears in Windows as a native COM port.

  • Interfaces: USB to RS-422/485, terminal block for the EZ-ARRAY MQDMC-5.. cable
  • Supply: from the USB port, no external power supply
  • Housing: 82x72.5x22.5 mm
  • Environment: IP10, NEMA 1, 0...+50 °C
  • Included: USB cable and software

For use with EZ-ARRAY the four-position DIP switch is set to S1 ON, S2-S4 OFF and the internal jumpers as shown in the datasheet. The EZ-ARRAY communication cable MQDMC-5.. is ordered separately.

Relays and converters
Analogue signal insulator IM31-22EX-I
In stock: 1 pcs
277.30 €
ATEX, IECEx, UL, CFMUS, TR CU, NEPSI, KOSHA; Installation in zone 2

Input circuits: 0/2…10 V or 0/4…20 mA 
Output circuits: 0/4…20 mA
Relays and converters
Level relay HRH-5, 24-240 Vac/dc, for 1 - 2 electrodes
In stock: 21 pcs
41.70 €
Relay is designed for monitoring levels in wells, basins, reservoirs, tanks,...
In one device you can choose the following configurations:
- One-level switch of conductive liquids (by connecting H and D).
- Two-level switch of conductive liquids.
One-state device monitors one level, two-state device monitors two levels (switches on one level and switches off on another level).
Adjustable time delay on the output (0.5 - 10s).
Sensitivity adjustable by a potentiometer (5 - 100 kΩ).
Measuring frequency 10 Hz prevents polarization of liquid and raising oxidation of measuring probes.
Galvanically separated supply voltage UNI 24 to 240 V AC/DC.
Relays and converters
Analogue signal converter 0/4-20 mA for transducers, Ethernet
In stock: 1 pcs
182.00 €

Dual channel p-line Web Sensor from 0-20mA (4-20mA) to Ethernet. Remote alarm.

Relays and converters
Universal transmitter AR593, RTD/TC/mA/V input, 0/4-20mA and 0/2-10V output, isolated, DIN rail
Out of stock
162.00 €

AR593 is an APAR programmable transmitter and signal isolator for 35 mm DIN rail. It converts an RTD, thermocouple, mA, V, mV or resistance input into a current and a voltage output at the same time, with 1.5 kV isolation between input, output and supply.

  • Input: Pt100/Pt500/Pt1000/Ni100 2- or 3-wire, thermocouple J/K/S/B/R/T/E/N, 0/4-20 mA, 0-10 V, 0-60 mV, 0-2500 Ω
  • Outputs: 0/4-20 mA active (load ≤ 500 Ω) and 0/2-10 V, also inverted
  • Accuracy: 0.1 % of range, thermocouples additionally <2 °C
  • Supply: 24 VAC/DC (18-50 VDC, 13-35 VAC), <850 mW
  • Response time: 360 ms, adjustable 0.24...1.6 s
  • Housing: 35 mm DIN rail, IP20, 0...65 °C

Factory setting is Pt100, 0...500 °C, 4-20 mA and 0-10 V; another input or range is set with an APAR programmer, or by APAR when specified with the order (e.g. AR593 / J / 0..20 mA / 100..600 °C). The current output is active and cannot be used in a loop-powered 2-wire circuit. A red LED shows range exceedance, sensor fault or alarm.

Relays and converters
Level relay HRH-8, 230 VAC
In stock: 5 pcs
65.00 €
  • Relay is designed to control the level of conductive liquids in wells, tanks, pools, tankers, reservoirs,... (replacement HRH-1).
  • Galvanically isolated supply and guard circuits.
  • Within one device, the following confi gurations can be selected:
    - 2x one-level monitoring (in separate tanks)
    - 1x two-level monitoring (in one tank) - pumping from one tank to another.
  • DIP switch selection on the front panel (8 functions).
  • Adjustable probe sensitivity (for each probe separately).
  • Adjustable relay switching delay (for each probe separately).
  • 10 Hz watch frequency prevents polarization of the liquid and increases resistance to interference by network frequency
Relays and converters
Transmitter TXBLOCK-USB, universal input, 4-20 mA
In stock: 143 pcs
45.00 €
The TxBlock-USB delivers real benefits that make a difference in daily industrial operations:
• Efficiency: A single device that serves multiple applications, reducing stock complexity.
• Cost Savings: Lower maintenance and operational costs thanks to its robustness and durability.
• Reliability: Typical accuracy of 0.1% of the span, ensuring reliable measurements even in challenging conditions.
• Simplicity: Quick and easy configuration through a micro-B USB cable using the SigNow configuration software in a Windows® environment.
Main Technical Features
• Power Supply: 10 to 35 Vdc, ensuring flexibility for different industrial systems.
• Universal Inputs: Compatible with thermocouples (J, K, T, E, N, R, S, B), Pt100, Pt1000, NTC, and voltage signals (0-50 mV), allowing broad application in various sectors.
• Linearized Output: Reliable transmission of 4-20 mA signals with zero offset adjustment via configuration software.
• Electromagnetic Immunity: Designed to meet global standards, ensuring stability even in harsh industrial environments.
• Resolution: 2 µA, ensuring high measurement precision.
• Compact Dimensions: Only 43.5 mm in diameter and 20.5 mm in height, ideal for head mounting.
Relays and converters
Temperature transmitter TxRail-USB 4-20 mA, 0-10 Vdc out, DIN rail
In stock: 17 pcs
72.00 €
DIN Rail Temperature Transmitter
TxRail-USB is an USB configurable DIN rail mount temperature transmitter.
It allows selection and configuration of input type, measurement range, output type and calibration. Its output can be set to either loop powered 4-20mA or 0-10V.
Highly accurate and user-friendly, the TxRail-USB performs well from simple to sophisticated measurement applications.
Relays and converters
Relay output module 5A (2 slots)
In stock: 3 pcs
24.10 €
CG-2R5 ClickNGo Module has 2 x 5A relay outputs and was designed to work as an expansion module for NOVUS line of modular controllers. CG-2R5 must be attached to the controller dock (to insert the module to the controller, make sure the device is turned off). Once inserted, it will be automatically recognized. Its configuration parameters will be displayed according to the slot in which the module has been attached to the dock. You can configure this module directly at the controller, through the QuickTune software, or through the QuickTune Mobile.
Relays and converters
Signal converter S15C-I-KQ, 4-20mA to IO-Link, 18-30VDC, M12 4-pin
In stock: 1 pcs
95.00 €

S15C-I-KQ is a Banner S15C series in-line converter that reads a 4-20 mA current signal and passes the value to an IO-Link master as process data in µA. It screws directly onto the sensor connector or into the cable run.

  • Precision: accuracy 0.5 %, resolution 14 bit
  • Input: analog current 4...20 mA, input impedance approx. 450 Ω
  • Communication: IO-Link device, switch points SP1 and SP2 set over IO-Link
  • Supply: 18...30 VDC, max. 50 mA; pass-through current max. 1 A
  • Housing: over-moulded PVC body, nickel-plated brass coupling nuts, 15x58 mm
  • Environment: IP65, IP67, IP68, -40...+70 °C
  • Connection: integral 4-pin M12 male and female

A shielded cable is required on the sensor side, with the shield tied to the blue wire. It needs an IO-Link master port; the IODD is available from Banner.

Vibration per IEC 60068-2-6, shock per IEC 60068-2-27 (15 G, 11 ms).

Relays and converters
Signal converter S15C-I-MQ, 4-20mA to Modbus, 10-30VDC, M12 4-pin
In stock: 2 pcs
95.00 €

S15C-I-MQ is a Banner S15C series in-line converter that reads an analog current signal (4...20 mA) and writes the value to a Modbus register over RS-485. It screws directly onto the sensor connector or into the cable run.

  • Precision: accuracy 1.5 % of full scale, resolution 12 bit
  • Input: analog current 4...20 mA, internal resistance 100 Ω
  • Communication: Modbus server, RS-485; Current (mA) = register value / 1000, min/max alarm register
  • Supply: 10...30 VDC, max. 50 mA; pass-through current max. 4 A
  • Housing: over-moulded PVC body, nickel-plated brass coupling nuts, 15x58 mm
  • Environment: IP65, IP67, IP68, -40...+70 °C
  • Connection: integral 4-pin M12 male and female

Turns a single analog transmitter into a Modbus device for a DXM controller or a PLC with RS-485. Modbus settings are made with Banner Sensor Configuration Software and the BWA-UCT-900 adapter cable, ordered separately.

Vibration per IEC 60068-2-6, shock per IEC 60068-2-27 (15 G, 11 ms).

Relays and converters
Digital Load cell indicator T1-4, analog/digital, 4 input channels
In stock: 1 pcs
355.00 €
Weight transmitter and indicator for
• 4 independent reading channels
• Suitable for back panel
• Six-digit semi-alphanumeric display
• 7 segment 8 mm height
• 6 signalling LEDs
• Four buttons for the system calibration (behind display)
• Removable screw terminal blocks
• The T1-4 Channel Transmitter can be configured and managed,
using the free “Instrument Manager” PC software,
which you can download from our website.
Relays and converters
Signal converter R45C-PF-IQ, PFM to 4-20mA, 12-30VDC, M12 5-pin
In stock: 3 pcs
141.00 €

R45C-PF-IQ is a Banner R45C series in-line converter that turns the pulse-frequency modulated (PFM) output of a sensor into a 4-20 mA analog current. It lets a sensor with a PFM output feed a standard analog input.

  • Precision: accuracy 0.5 %, resolution 14 bit
  • Input: PFM 100...600 Hz
  • Output: analog current 4...20 mA
  • Supply: 12...30 VDC, max. 50 mA
  • Housing: over-moulded PVC body, nickel-plated brass coupling nuts
  • Environment: IP65, IP67, IP68, -40...+70 °C
  • Connection: integral 5-pin M12 male and female

Two amber LEDs show whether the PFM input and the analog output are within their valid range; both go off when no sensor is connected.

Vibration per IEC 60068-2-6, shock per IEC 60068-2-27 (15 G, 11 ms).

Relays and converters
Transmitter TxIsoPack-USB, isolated 4...20mA
In stock: 3 pcs
98.00 €
Isolated Temperature Transmitter
TxIsoPack-USB is a fully isolated 4 to 20 mA two-wire loop powered temperature transmitter for in-head assembly.
Complete sensor type selection and range configuration is achieved by connecting the device directly to a PC USB port thus not requiring any other interface, special converter or any additional driver.
The isolated and linearized current output represents the sensor input signal according to the temperature sensor selected.
Relays and converters
Isolating switching amplifier IM1-22EX-R/24VDC, 2-channel, 2 relays NO, 10-30VDC
Out of stock
139.70 €

IM1-22EX-R/24VDC is a 2-channel TURCK isolating switching amplifier with intrinsically safe input circuits and two relay outputs, each with one NO contact. Six front switches set the output mode (NO/NC) and switch wire-break and short-circuit monitoring on or off separately for each channel.

  • Channels: 2 inputs for NAMUR sensors (EN 60947-5-6) or potential-free contacts
  • Outputs: 2 relays, 1 NO each, 30 V DC / 250 V AC, ≤2 A, ≤500 VA / 60 W
  • Supply: 10...30 V DC (24 V DC nominal)
  • Housing: polycarbonate/ABS, 104 x 18 x 110 mm, DIN rail (NS35) or panel mounting
  • Connection: screw terminals, 1 x 2.5 mm² / 2 x 1.5 mm²
  • Environment: IP20, -25...+60 °C

Used to pass NAMUR sensor or contact signals from a hazardous area to a relay input in the control cabinet. With monitoring switched on, an input fault turns the channel LED red and the output relay drops out. Mechanical contacts need either monitoring switched off or the resistor wiring shown in the datasheet.

Approvals: ATEX, CFMUS, TR CU.

Relays and converters
Isolating transducer IM33-22EX-HI/24VDC
Out of stock
390.20 €
ATEX, IECEx, UL, CFMUS, TR CU, CCOE, Kosha; Installation in zone 2

Input circuits: 0/4…20 mA
Output circuits: 0/4…20 mA
Relays and converters
Frequency transducer IM12-FI01-2SF-2I-C0/24VDC, 2-channel, 0/4-20mA, 10-30VDC, SIL2
Out of stock
326.90 €

IM12-FI01-2SF-2I-C0/24VDC is a 2-channel TURCK frequency transducer and pulse counter that transfers frequency signals up to 20 kHz with galvanic isolation and converts them to 0/4...20 mA. It is parameterised from a PC via FDT and IODD.

  • Channels: 2 frequency inputs for NAMUR sensors (EN 60947-5-6) or contacts, 0.0006...1,200,000 rpm
  • Outputs: 2 x 0/4...20 mA, source or sink (15...28 V), load ≤0.8 kΩ
  • Configuration: PC via FDT and IODD; inputs assignable as E1, E2, E1-E2 or E2-E1
  • Supply: 10...30 V DC, ≤3 W
  • Housing: polycarbonate/ABS, 120 x 12.5 x 117 mm, DIN rail (NS35), removable screw terminals
  • Environment: IP20, -25...+70 °C

Used for speed monitoring of shafts and conveyors where the pulse sensor sits in a hazardous area. Wire break and short circuit on the input are monitored; the fault current can be set to < 3.5 mA or > 21.5 mA. A PC connection is needed for parameterisation.

Approvals: ATEX, cULus; for use in ATEX Zone 2. SIL 2.

Relays and converters
Isolating switching amplifier IM12-22EX-R, 2-channel, 2 relays NO, 20-125VDC/20-250VAC
Out of stock
149.70 €

IM12-22EX-R is a 2-channel TURCK isolating switching amplifier with intrinsically safe input circuits and two relay outputs, each with one NO contact. Front switches set the output mode (NO/NC) and signal multiplexing, where channel 1 drives both outputs.

  • Channels: 2 inputs for NAMUR sensors (EN 60947-5-6) or potential-free contacts
  • Outputs: 2 relays, 1 NO each, 30 V DC / 250 V AC, ≤2 A, ≤500 VA / 60 W
  • Supply: 20...125 V DC / 20...250 V AC (40...70 Hz)
  • Housing: polycarbonate/ABS, 104 x 18 x 110 mm, DIN rail (NS35) or panel mounting
  • Connection: screw terminals, 1 x 2.5 mm² / 2 x 1.5 mm²
  • Environment: IP20, -25...+70 °C

Used to pass NAMUR sensor or potential-free contact signals from a hazardous area to a relay input in the control cabinet. A green Pwr LED shows readiness and a yellow LED shows the output switching state.

Approvals: ATEX, IECEx, cUL, cFM, CSA, TR CU; for use in Zone 2.

Relays and converters
Isolating switching amplifier IM12-DI01-2S-2T-0/24VDC, 2-channel, 2 transistor outputs, 10-30VDC, SIL2
Out of stock
135.90 €

IM12-DI01-2S-2T-0/24VDC is a 2-channel TURCK isolating switching amplifier in a 12.5 mm housing with two potential-free transistor outputs up to 10 kHz. It runs either as two separate channels or with channel 1 doubled onto both outputs.

  • Channels: 2 inputs for NAMUR sensors (EN 60947-5-6) or potential-free contacts
  • Outputs: 2 potential-free, short-circuit-proof transistors, ≤30 V DC, 0.1 A, ≤10 kHz
  • Supply: 10...30 V DC, ≤0.8 W
  • Housing: polycarbonate/ABS, 120 x 12.5 x 117 mm, DIN rail (NS35)
  • Connection: removable screw terminals, 0.2...2.5 mm²
  • Environment: IP20, -25...+70 °C

DIP switches on the front set the output mode, input circuit monitoring and the operating mode. An input fault makes the red LED flash according to NE44 and blocks the transistor of that channel. Mechanical contacts need either monitoring switched off or the resistor wiring shown in the datasheet.

Approvals: ATEX, cULus; for use in ATEX Zone 2. Usable in safety circuits up to SIL 2 (IEC 61508).

Relays and converters
Temperature measuring amplifier IM12-TI02-2TCURTDR-2I-C0/24VDC, TC/RTD, 2-channel, 0/4-20mA, SIL2
Out of stock
321.20 €

IM12-TI02-2TCURTDR-2I-C0/24VDC is a 2-channel TURCK temperature measuring amplifier for thermocouples, RTDs, resistors and mV signals. It converts the inputs to galvanically isolated 0/4...20 mA outputs; cold junction compensation can be internal, external or a fixed value.

  • Inputs: 2 x thermocouple (IEC 60584, DIN 43710), -150...+150 mV, RTD (IEC 60751, DIN 43760) or 0...5 kΩ, 2- or 3-wire
  • Outputs: 2 x 0/4...20 mA, source or sink (15...28 V); inputs assignable as E1, E2, E1-E2 or E2-E1
  • Configuration: PC via FDT and IODD
  • Supply: 10...30 V DC, ≤2.7 W
  • Housing: polycarbonate/ABS, 120 x 12.5 x 117 mm, DIN rail (NS35), removable screw terminals
  • Environment: IP20, -25...+70 °C

Used where a mix of thermocouples and RTDs from a hazardous area has to reach the control system as current signals. With a 3-wire RTD connection, the lead resistances must be equal. Input faults are indicated according to NE44, and a PC connection is needed for parameterisation.

Approvals: ATEX, cULus; for use in ATEX Zone 2. SIL 2.

Relays and converters
Temperature measuring amplifier IM34-12EX-RI
Out of stock
371.60 €
ATEX, IECEx, CFMUS, UL, TR CU, INMETRO, CCOE, NEPSI, KOSHA; Installation in zone 2
Relays and converters
Contactor 230V50HZ/240V60HZ
Out of stock
43.00 €

Kontaktors DILM15-01-230AC-E EATON Piegāde 1 nedēļa

Relays and converters
Contactor DILEM-10 (230VAC) (XTMC6A10) EATON
Out of stock
45.00 €

Kontaktors DILEM-10 (230VAC) (XTMC6A10) EATON Piegāde 1 nedēļa

Relays and converters
Temperature measuring amplifier IM12-TI01-2RTDR-2I-C0/24VDC, RTD, 2-channel, 0/4-20mA, SIL2
In stock: 2 pcs
290.40 €

IM12-TI01-2RTDR-2I-C0/24VDC is a 2-channel TURCK temperature measuring amplifier for resistance thermometers. It converts two RTD or resistance signals to galvanically isolated 0/4...20 mA outputs and also outputs the difference of the two inputs.

  • Inputs: 2 x RTD (Pt50, Pt100, Pt500, Pt1000, Ni50, Ni100, Ni500 and others) or 0...5 kΩ, 2-, 3- or 4-wire
  • Outputs: 2 x 0/4...20 mA, source or sink (15...28 V); inputs assignable as E1, E2, E1-E2 or E2-E1
  • Configuration: PC via FDT and IODD
  • Supply: 10...30 V DC, ≤2.7 W
  • Housing: polycarbonate/ABS, 120 x 12.5 x 117 mm, DIN rail (NS35), removable screw terminals
  • Environment: IP20, -25...+70 °C

Used to bring Pt100 and similar sensors from a hazardous area into a control system as a standard current signal. Wire break and short circuit are indicated by a flashing red LED according to NE44, and the fault current can be set to < 3.5 mA or > 21.5 mA. A PC connection is needed for parameterisation.

Approvals: ATEX, cULus; for use in ATEX Zone 2. SIL 2.

Relays and converters
Temperature measuring amplifier IM34-11EX-I
Out of stock
352.90 €
ATEX, IECEx, CFMUS, UL, TR CU, INMETRO, CCOE, NEPSI, KOSHA; Installation in zone 2
Relays and converters
Signal converter S15C-B22-MQ, discrete I/O to Modbus, 12-30VDC, M12 4-pin
In stock: 1 pcs
95.00 €

S15C-B22-MQ is a Banner S15C series in-line converter with two discrete channels that can each be set as NPN or PNP input or output. Channel states are read and written through Modbus registers over RS-485.

  • Inputs and outputs: 2 discrete channels, NPN or PNP set per channel; output load 50 mA, ON-state voltage drop 2 V
  • Communication: Modbus server, RS-485, default 19.2 kbit/s
  • Supply: 12...30 VDC, max. 50 mA; pass-through current max. 1 A
  • Housing: over-moulded PVC body, nickel-plated brass coupling nuts, 15x58 mm
  • Environment: IP65, IP67, IP68, -40...+70 °C
  • Connection: integral 4-pin M12 male and female

Turns a discrete sensor or actuator into a Modbus device for a DXM controller or a PLC with RS-485. Settings are made with Banner SNAP SIGNAL Configuration Software.

Vibration per IEC 60068-2-6, shock per IEC 60068-2-27 (15 G, 11 ms).

Relays and converters
Signal converter S15C-U-MQ, 0-10V to Modbus, 10-30VDC, M12 4-pin
Out of stock
95.00 €

S15C-U-MQ is a Banner S15C series in-line converter that reads an analog voltage signal (0...10 V) and writes the value to a Modbus register over RS-485. It screws directly onto the sensor connector or into the cable run.

  • Precision: accuracy 1.5 % of full scale, resolution 12 bit
  • Input: analog voltage 0...10 V
  • Communication: Modbus server, RS-485; Voltage = register value / 1000, min/max alarm register
  • Supply: 10...30 VDC, max. 50 mA; pass-through current max. 4 A
  • Housing: over-moulded PVC body, nickel-plated brass coupling nuts, 15x58 mm
  • Environment: IP65, IP67, IP68, -40...+70 °C
  • Connection: integral 4-pin M12 male and female

Turns a single analog transmitter into a Modbus device for a DXM controller or a PLC with RS-485. Modbus settings are made with Banner Sensor Configuration Software and the BWA-UCT-900 adapter cable, ordered separately.

Vibration per IEC 60068-2-6, shock per IEC 60068-2-27 (15 G, 11 ms).

Relays and converters
Isolating switching amplifier IM1-22EX-R, 2-channel, 2 relays NO, 20-125VDC/20-250VAC, SIL2
Out of stock
146.50 €

IM1-22EX-R is a 2-channel TURCK isolating switching amplifier with intrinsically safe input circuits and two relay outputs, each with one NO contact. Six front switches set the output mode (NO/NC) and switch wire-break and short-circuit monitoring on or off separately for each channel.

  • Channels: 2 inputs for NAMUR sensors (EN 60947-5-6) or potential-free contacts
  • Outputs: 2 relays, 1 NO each, 30 V DC / 250 V AC, ≤2 A, ≤500 VA / 60 W
  • Supply: 20...125 V DC / 20...250 V AC (40...70 Hz)
  • Housing: polycarbonate/ABS, 104 x 18 x 110 mm, DIN rail (NS35) or panel mounting
  • Connection: screw terminals, 1 x 2.5 mm² / 2 x 1.5 mm²
  • Environment: IP20, -25...+70 °C

Used to pass NAMUR sensor or contact signals from a hazardous area to a relay input in the control cabinet. With monitoring switched on, an input fault turns the channel LED red and the output relay drops out. Mechanical contacts need either monitoring switched off or the resistor wiring shown in the datasheet.

Approvals: ATEX, IECEx, UL, CFMUS, CSA, TR CU; for use in Zone 2. SIL 2 according to exida FMEDA.

Relays and converters
Analogue sensor 4-20 mA interface, 2 x 4-20mA, IP67, NB-IoT
Out of stock
172.20 €
- Device is equipped with analog interfaces (2 x 4-20mA).
- External sensors can be powered by the device or by external power supply
- Data from the analog sensors is presented as current (4-20 mA)
- IP67 protection
- 40,000 measurements memory
- IP30 version EAN: 5905309601819
Relays and converters
Isolating switching amplifier IM12-22EX-R/24VDC, 2-channel, 2 relays NO, 10-30VDC
Out of stock
139.20 €

IM12-22EX-R/24VDC is a 2-channel TURCK isolating switching amplifier with intrinsically safe input circuits and two relay outputs, each with one NO contact. Front switches set the output mode (NO/NC) and signal multiplexing, where channel 1 drives both outputs.

  • Channels: 2 inputs for NAMUR sensors (EN 60947-5-6) or potential-free contacts
  • Outputs: 2 relays, 1 NO each, 30 V DC / 250 V AC, ≤2 A, ≤500 VA / 60 W
  • Supply: 10...30 V DC (24 V DC nominal)
  • Housing: polycarbonate/ABS, 104 x 18 x 110 mm, DIN rail (NS35) or panel mounting
  • Connection: screw terminals, 1 x 2.5 mm² / 2 x 1.5 mm²
  • Environment: IP20, -25...+60 °C

Used to pass NAMUR sensor or potential-free contact signals from a hazardous area to a relay input in the control cabinet. A green Pwr LED shows readiness and a yellow LED shows the output switching state.

Approvals: ATEX, CFMUS, TR CU.

Relays and converters
I/O Hub R95C-4B4UI-MQ, 4 discrete + 4 analog ports, Modbus RTU, 12-30VDC, M12
Out of stock
314.00 €

R95C-4B4UI-MQ is a Banner R95C series Modbus hub with eight M12 ports: four with two discrete channels each and four analog ports for voltage or current, each usable as input or output. All values are read and written through Modbus registers over RS-485.

  • Discrete: ports 1-4, 2 channels each, NPN or PNP set per channel, output load 200 mA; delay modes, counters, PFM output 0...600 Hz
  • Analog: ports 5-8, input 0...11000 mV or 0...24000 µA, output 0...10000 mV or 4000...20000 µA
  • Communication: Modbus RTU server, RS-485
  • Supply: 12...30 VDC, max. 400 mA without load; total pass-through current max. 4 A
  • Housing: over-moulded PVC body, nickel-plated brass coupling nuts, 50x95 mm
  • Environment: IP65, IP67, IP68, -40...+70 °C
  • Connection: 8x 4-pin M12 female, 1x 5-pin M12 male to the Modbus line

Any analog input can be mirrored to an analog output port or as a PFM signal to a discrete port without PLC logic. Settings are made with Banner SNAP SIGNAL Configuration Software; M12 cordsets are ordered separately.

Vibration per IEC 60068-2-6, shock per IEC 60068-2-27 (15 G, 11 ms).

Relays and converters
Signal converter R45C-MUU-UUQ, Modbus RTU, 2x 0-10V in/out, 12-30VDC, M12
Out of stock
197.00 €

R45C-MUU-UUQ is a Banner R45C series in-line converter with two analog analog voltage ports, each usable as input or output, and a Modbus RTU connection. Input values are written to Modbus registers, and values written to the output registers are produced as analog voltage.

  • Precision: accuracy 0.5 %, resolution 14 bit
  • Inputs and outputs: 2 ports, analog voltage in and out, range 0...11000 mV; input impedance approx. 14.3 kΩ; output load min. 2.5 kΩ
  • Communication: Modbus RTU server, RS-485, default 19.2 kbit/s
  • Supply: 12...30 VDC, max. 50 mA; pass-through current max. 4 A
  • Housing: over-moulded PVC body, nickel-plated brass coupling nuts
  • Environment: IP65, IP67, IP68, -40...+60 °C
  • Connection: 5-pin M12 male (Modbus), 2x 4-pin M12 female (analog)

Out-of-range output values go to a selectable level after 2 s: Low (0 V or 3.5 mA), High (10.5 V or 20.5 mA) or Hold. Modbus settings are made with Banner SNAP SIGNAL Configuration Software.

Vibration per IEC 60068-2-6, shock per IEC 60068-2-27 (15 G, 11 ms).

Relays and converters
I/O Hub R95C-8B21-MQ, 8-port discrete, Modbus RTU, 12-30VDC, M12
Out of stock
310.00 €

R95C-8B21-MQ is a Banner R95C series Modbus hub with eight M12 ports, each carrying two discrete channels that can be set as NPN or PNP input or output. Channel states are read and written through Modbus registers over RS-485.

  • Ports: 8x M12 female, 2 discrete channels per port, NPN or PNP set per channel; output load 100 mA
  • Functions: ON/OFF delay, one-shot, retriggerable one-shot, pulse stretcher, totaliser; count, events per minute and duration per channel
  • Communication: Modbus RTU server, RS-485; any port signal can be mirrored to another port or to the host pin 5
  • Supply: 12...30 VDC, max. 400 mA; pass-through current max. 500 mA per port
  • Housing: over-moulded PVC body, nickel-plated brass coupling nuts, 50x95 mm
  • Environment: IP65, IP67, IP68, -40...+70 °C
  • Connection: 8x 4-pin M12 female, 1x 5-pin M12 male to the Modbus line

Collects up to 16 discrete signals at the machine onto one Modbus line, for example to a DXMR90 controller. Settings are made with Banner SNAP SIGNAL Configuration Software; M12 cordsets are ordered separately.

Vibration per IEC 60068-2-6, shock per IEC 60068-2-27 (15 G, 11 ms).

Relays and converters
I/O Hub R95C-8UI-MQ, 8-port analog in, Modbus RTU, 12-30VDC, M12
Out of stock
294.00 €

R95C-8UI-MQ is a Banner R95C series Modbus hub with eight M12 ports for analog voltage or current inputs. Each measured value is placed in its own Modbus register and read over RS-485.

  • Inputs: 8 ports, analog voltage 0...11000 mV or current 0...24000 µA; impedance approx. 14.3 kΩ (voltage) or 250 Ω (current)
  • Communication: Modbus RTU server, RS-485, default 19.2 kbit/s
  • Supply: 12...30 VDC, max. 400 mA; pass-through current max. 500 mA per port
  • Housing: over-moulded PVC body, nickel-plated brass coupling nuts, 50x95 mm
  • Environment: IP65, IP67, IP68, -40...+70 °C
  • Connection: 8x 4-pin M12 female, 1x 5-pin M12 male to the Modbus line

Brings eight analog transmitters onto one Modbus line at the machine instead of wiring each back to an analog input card. Settings are made with Banner SNAP SIGNAL Configuration Software; M12 cordsets are ordered separately.

Vibration per IEC 60068-2-6, shock per IEC 60068-2-27 (15 G, 11 ms).

Relays and converters
Signal converter R45C-MII-IIQ, Modbus RTU, 2x 4-20mA in/out, 12-30VDC, M12
Out of stock
197.00 €

R45C-MII-IIQ is a Banner R45C series in-line converter with two analog analog current ports, each usable as input or output, and a Modbus RTU connection. Input values are written to Modbus registers, and values written to the output registers are produced as analog current.

  • Precision: accuracy 0.5 %, resolution 14 bit
  • Inputs and outputs: 2 ports, analog current in and out, range 0...24000 µA; input impedance approx. 250 Ω; output load max. 1 kΩ at 24 VDC
  • Communication: Modbus RTU server, RS-485, default 19.2 kbit/s
  • Supply: 12...30 VDC, max. 50 mA; pass-through current max. 4 A
  • Housing: over-moulded PVC body, nickel-plated brass coupling nuts
  • Environment: IP65, IP67, IP68, -40...+60 °C
  • Connection: 5-pin M12 male (Modbus), 2x 4-pin M12 female (analog)

Out-of-range output values go to a selectable level after 2 s: Low (0 V or 3.5 mA), High (10.5 V or 20.5 mA) or Hold. Modbus settings are made with Banner SNAP SIGNAL Configuration Software.

Vibration per IEC 60068-2-6, shock per IEC 60068-2-27 (15 G, 11 ms).

Relays and converters
Signal converter R45C-K-IQ, IO-Link to analog current, 18-30VDC, M12 4-pin
Out of stock
118.00 €

R45C-K-IQ is a Banner R45C series in-line converter that turns an IO-Link process data value from the master into an analog current output. It lets an IO-Link master drive a valve, positioner or other device with a mA input.

  • Precision: accuracy 0.5 %, resolution 14 bit
  • Output: analog current, process data range 0...24000 µA; out-of-range level selectable Low 3.5 mA, High 20.5 mA or Hold
  • Communication: IO-Link device (male side)
  • Supply: 18...30 VDC, max. 50 mA; pass-through current max. 4 A
  • Housing: over-moulded PVC body, nickel-plated brass coupling nuts
  • Environment: IP65, IP67, IP68, -40...+70 °C
  • Connection: integral 4-pin M12 male and female

If the process data value leaves the valid range, the output moves to the selected level after 2 s. It needs an IO-Link master port.

Vibration per IEC 60068-2-6, shock per IEC 60068-2-27 (15 G, 11 ms).

Relays and converters
I/O Hub R90C-4B21-KQ, 4-port discrete, IO-Link, 18-30VDC, M12
Out of stock
201.00 €

R90C-4B21-KQ is a Banner R90C series IO-Link hub with four M12 ports, each carrying two discrete channels that can be set as NPN or PNP input or output. It brings non-IO-Link sensors and actuators onto one IO-Link master port.

  • Ports: 4x M12 female, 2 discrete channels per port, NPN or PNP set per channel; output load 100 mA
  • Functions: ON/OFF delay, one-shot, retriggerable one-shot, pulse stretcher, totaliser; count, events per minute and duration per channel
  • Communication: IO-Link device; any port signal can be mirrored to another port or to the host pin 2
  • Supply: 18...30 VDC, max. 100 mA; pass-through current max. 1 A per port
  • Housing: over-moulded PVC body, nickel-plated brass coupling nuts, 50x90 mm
  • Environment: IP65, IP67, IP68, -40...+70 °C
  • Connection: 4x 4-pin M12 female, 1x 4-pin M12 male to the master

Mounts on the machine next to the sensors, so one cable runs back to the IO-Link master instead of eight. It needs an IO-Link master port and M12 cordsets, ordered separately.

Vibration per IEC 60068-2-6, shock per IEC 60068-2-27 (15 G, 11 ms).

Relays and converters
Isolating transducer HART transparent, IMXK12-AI01-1I-1I-H0/24VDC/CC
In stock: 1 pcs
255.50 €

1-channel

    • Input circuits monitored for wire break and short circuit
    • Complete galvanic isolation
    • HART transparent
    • Removable cage clamp terminals
    • ATEX, IECEx, cULus
    • Use in zone 2
    • SIL 2