Safety I/O module RSIO-L5-6SI2SO-C, CIP Safety, 6 safety inputs, 2 OSSD outputs, L-coded M12 power, IP67
Out of stock
1,359.00 €

RSIO-L5-6SI2SO-C is a Banner RSio remote safety I/O block that brings six safety inputs and two OSSD outputs onto a CIP Safety over EtherNet/IP network. Each input port also accepts an In-Series Diagnostics (ISD) chain of up to 32 devices, 192 per block.

  • Inputs and outputs: 6 safety input ports, single or dual channel; 2 OSSD outputs, 1 A at 24 V DC, splittable; up to 12 PNP non-safe outputs
  • Communication: CIP Safety over EtherNet/IP, 10/100 Mbit/s, two M12 D-coded 4-pin Ethernet ports
  • Configuration: IP address on 3 rotary dials; set up from the safety PLC project, Studio 5000 recommended
  • Supply: 24 V DC ±20 %, 200 mA without load; 5-pin L-coded M12 power in and pass-through out, 8 A per circuit
  • Housing: glass-filled polyamide, epoxy-encapsulated, 261.9 x 73.9 x 39.4 mm; I/O on M12 A-coded 5-pin
  • Environment: IP65, IP67, -25...+70 °C, indoor use only

The block needs a safety PLC with CIP Safety on EtherNet/IP; Banner provides the EDS file and Studio 5000 AOI and UDT files. Input reaction time is 6 ms plus debounce (default 6 ms), output reaction time 5 ms.

Up to Category 4 and PL e (EN ISO 13849-1), SIL 3 (IEC 61508); EMC per IEC 61326-3-1. CE and UL.

Controllers
Safety I/O module RSIO-MA4-6SI2SO-C, CIP Safety, 6 safety inputs, 2 OSSD outputs, 7/8" Mini power, IP67
Out of stock
1,359.00 €

RSIO-MA4-6SI2SO-C is a Banner RSio remote safety I/O block that brings six safety inputs and two OSSD outputs onto a CIP Safety over EtherNet/IP network. Each input port also accepts an In-Series Diagnostics (ISD) chain of up to 32 devices, 192 per block.

  • Inputs and outputs: 6 safety input ports, single or dual channel; 2 OSSD outputs, 1 A at 24 V DC, splittable; up to 12 PNP non-safe outputs
  • Communication: CIP Safety over EtherNet/IP, 10/100 Mbit/s, two M12 D-coded 4-pin Ethernet ports
  • Configuration: IP address on 3 rotary dials; set up from the safety PLC project, Studio 5000 recommended
  • Supply: 24 V DC ±20 %, 200 mA without load; 4-pin 7/8" Mini power in and pass-through out, 8 A per circuit
  • Housing: glass-filled polyamide, epoxy-encapsulated, 261.9 x 73.9 x 39.4 mm; I/O on M12 A-coded 5-pin
  • Environment: IP65, IP67, -25...+70 °C, indoor use only

The block needs a safety PLC with CIP Safety on EtherNet/IP; Banner provides the EDS file and Studio 5000 AOI and UDT files. Input reaction time is 6 ms plus debounce (default 6 ms), output reaction time 5 ms.

Up to Category 4 and PL e (EN ISO 13849-1), SIL 3 (IEC 61508); EMC per IEC 61326-3-1. CE and UL.

Controllers
Safety relay RSr-L-SIL-8A-Q, OSSD input, 2 NO 8A, latch reset, 24VDC, SIL 3 / PL e, IP67
Out of stock
363.00 €

RSr-L-SIL-8A-Q is a remote safety relay from Banner's RSr family. It converts the OSSD outputs of a safety device into two volt-free normally open relay contacts, so a light curtain, a safety I/O block or a safety PLC can switch loads that do not tolerate OSSD test pulses. This is the latch model: after a stop the outputs stay off until a reset signal is applied on the A-code port.

  • Input: one dual-channel OSSD pair, ON threshold > 15 V DC, OFF below 5 V DC
  • Output: two normally open safety contacts, 8 A at 24 V DC (DC1) per IEC/EN 60947-5-1
  • Supply: 24 V DC ±20 %, under 100 mA, approximately 2 W
  • Response time 20 ms maximum, minimum OFF-state recovery 400 ms
  • Housing: thermoplastic polyurethane, IP65 / IP67, 138 × 50 × 27.8 mm, −25 °C to +60 °C
  • Connection: four 5-pin M12 connectors — two A-code for signals and reset, two L-code for the switched power

The relay mounts directly on the machine with two M4 screws or a bracket, so distributed safety outputs can switch motors, valves and brakes without a control cabinet. There are no DIP switches and nothing to program. Four LED indicators show status, fault, both safety inputs and the relay output.

SIL 3 per IEC 61508 and EN 62061, Category 4 / PL e per EN ISO 13849-1; CE marked and UL listed.

Controllers
Safety relay RSr-L-SIT-8A-Q, OSSD input, 2 NO 8A, automatic reset, AUX output, 24VDC, SIL 3 / PL e, IP67
Out of stock
318.00 €

RSr-L-SIT-8A-Q is a remote safety relay from Banner's RSr family. It converts the OSSD outputs of a safety device into two volt-free normally open relay contacts, so a light curtain, a safety I/O block or a safety PLC can switch loads that do not tolerate OSSD test pulses. This is the trip model: the contacts follow the safety inputs directly, and pin 5 of the A-code port carries an auxiliary output that mirrors the relay state.

  • Input: one dual-channel OSSD pair, ON threshold > 15 V DC, OFF below 5 V DC
  • Output: two normally open safety contacts, 8 A at 24 V DC (DC1) per IEC/EN 60947-5-1, plus a 24 V DC 70 mA solid-state AUX output
  • Supply: 24 V DC ±20 %, under 100 mA, approximately 2 W
  • Response time 20 ms maximum, minimum OFF-state recovery 400 ms
  • Housing: thermoplastic polyurethane, IP65 / IP67, 138 × 50 × 27.8 mm, −25 °C to +60 °C
  • Connection: four 5-pin M12 connectors — two A-code for signals and the AUX output, two L-code for the switched power

The relay mounts directly on the machine with two M4 screws or a bracket, so distributed safety outputs can switch motors, valves and brakes without a control cabinet. There are no DIP switches and nothing to program. Four LED indicators show status, fault, both safety inputs and the relay output.

SIL 3 per IEC 61508 and EN 62061, Category 4 / PL e per EN ISO 13849-1; CE marked and UL listed.