Skip to Content
Filters
Shop
49 items found.
Clear Filters
TURCK
Relays and converters
Analogue signal insulator IM31-22EX-I
In stock: 1 pcs
277.30 €
ATEX, IECEx, UL, CFMUS, TR CU, NEPSI, KOSHA; Installation in zone 2

Input circuits: 0/2…10 V or 0/4…20 mA 
Output circuits: 0/4…20 mA
HMI
Touch display TX705-P3CV01, 5", CODESYS V3 PLC, IP66 front
In stock: 1 pcs
721.00 €

TX705-P3CV01 is a 5" touch display from the TURCK TX700 series with a built-in CODESYS V3 PLC, TARGET and WEB VISU visualisation. The PLC program and the screens are built in CODESYS V3 and loaded into the device over Ethernet.

  • Display: 5" TFT, 800 x 480 (WVGA), 16:9, 64K colours, 300 cd/m², capacitive glass front, dimmable to 0 %
  • Communication: 2 x RJ45 Ethernet 10/100 Mbit, 1 x RS232/RS485/RS422, 1 x USB host, SD card slot
  • Expansion: 1 slot for up to 2 plug-in modules (I/O, CANopen, PROFIBUS DP, RS485, RS232, LTE/Wi-Fi)
  • PLC: CODESYS V3.5.12.10, IEC 61131-3 (IL, LD, FBD, SFC, ST), 20000 kB program memory, 63 kB retain memory; ARM Cortex A8, 1 GHz, 512 MB RAM, 4 GB Flash, battery-backed clock
  • Supply: 24 VDC (10...32 VDC), max. 0.6 A
  • Housing: metal, front 147 x 107 x 52 mm, cut-out 136 x 96 mm, mounting depth 52+8 mm
  • Environment: IP66 front, IP20 rear, NEMA 12/4X; -20...+60 °C, 5...85 % RH non-condensing

Built into a cabinet door or control desk. Mounting brackets and the power connector come in the 5" TX700 mounting kit, available as an accessory; I/O and fieldbus modules plug into the expansion slots and are ordered separately.

HMI
Touch display TX715-P3CV01, 15.6", CODESYS V3 PLC, IP66 front
Out of stock
2,547.00 €

TX715-P3CV01 is a 15.6" touch display from the TURCK TX700 series with a built-in CODESYS V3 PLC, TARGET and WEB VISU visualisation. The PLC program and the screens are built in CODESYS V3 and loaded into the device over Ethernet.

  • Display: 15.6" TFT, 1366 x 768 (HD), 16:9, 16M colours, 400 cd/m², capacitive glass front, dimmable to 0 %
  • Communication: 3 x RJ45 Ethernet 10/100 Mbit, 1 x RS232/RS485/RS422, 2 x USB host (v2.0, max. 500 mA), SD card slot
  • Expansion: 2 slots for up to 4 plug-in modules (I/O, CANopen, PROFIBUS DP, RS485, RS232, LTE/Wi-Fi)
  • PLC: CODESYS V3.5.12.10, IEC 61131-3 (IL, LD, FBD, SFC, ST), 20000 kB program memory, 63 kB retain memory; ARM Cortex A9, Quad core 800 MHz, 2048 MB RAM, 8 GB Flash, battery-backed clock
  • Supply: 24 VDC (10...32 VDC), max. 1.2 A
  • Housing: metal, front 422 x 267 x 56 mm, cut-out 411 x 256 mm, mounting depth 56+8 mm
  • Environment: IP66 front, IP20 rear, NEMA 12/4X; -20...+60 °C, 5...85 % RH non-condensing

Built into a cabinet door or control desk. Mounting brackets and the power connector come in the 15.6" TX700 mounting kit, available as an accessory; I/O and fieldbus modules plug into the expansion slots and are ordered separately.

HMI
7" TX500 HMI/PLC Series TX507E-P3CV01
Out of stock
1,100.00 €

7” Display - CODESYS V3 PLC with TARGET and WEB VISU

High-Quality Metal Housing with a Resistive Touch Screen

Ident. no.: 6828103
    • 7" TFT wide screen color display
    • LED backlight
    • 800 x 480 pixel resolution
    • 64 K colors
    • Resistive touch screen
    • 2 RJ45 Ethernet ports with integrated switch
    • 1 serial interface (RS232, RS485, RS422)
    • 2 USB host ports
    • 1 SD card slot
PLC and FLC
Compact PLC TBEN-L5-PLC-10
Out of stock
839.00 €
  • PROFINET controller/device
  • EtherNet/IP scanner/device
  • EtherCAT master
  • Modbus TCP master/slave
  • Modbus RTU master/slave
  • CANopen manager/device
  • SAE J1939 manager
  • Serial interfaces RS232/RS485
  • Ethernet 2 × M12, 4-pin, D-coded
  • Switched or dual MAC mode
  • 10 Mbps/100 Mbps
Displays
Touch display TX707HB-P3CV01, 7", CODESYS V3 PLC, IP66 front, sunlight readable
Out of stock
1,602.00 €

TX707HB-P3CV01 is a 7" touch display from the TURCK TX700 series with a built-in CODESYS V3 PLC, TARGET and WEB VISU visualisation. The HB version has a brighter 600 cd/m² screen, bonded with LOCA to reduce reflection, for readability in sunlight, and an all-metal housing with a protective coating on the PCB.

  • Display: 7" TFT, 800 x 480 (WVGA), 16:9, 16M colours, 600 cd/m², capacitive glass front, dimmable to 0 %
  • Communication: 3 x RJ45 Ethernet 10/100 Mbit, 1 x RS232/RS485/RS422, 2 x USB host (v2.0, max. 500 mA), SD card slot
  • Expansion: 2 slots for up to 4 plug-in modules (I/O, CANopen, PROFIBUS DP, RS485, RS232, LTE/Wi-Fi)
  • PLC: CODESYS V3.5.12.10, IEC 61131-3 (IL, LD, FBD, SFC, ST), 20000 kB program memory, 63 kB retain memory; ARM Cortex A9, Dual core 800 MHz, 1024 MB RAM, 4 GB Flash, battery-backed clock
  • Supply: 24 VDC (10...32 VDC), max. 0.7 A
  • Housing: metal, front 187 x 147 x 47 mm, cut-out 176 x 136 mm, mounting depth 47+8 mm
  • Environment: IP66 front, IP20 rear, NEMA 12/4X; -20...+60 °C, 5...85 % RH non-condensing

Built into a cabinet door or control desk. Mounting brackets and the power connector come in the 7" TX700 mounting kit, available as an accessory; I/O and fieldbus modules plug into the expansion slots and are ordered separately.

Relays and converters
Isolating switching amplifier IM1-22EX-R/24VDC, 2-channel, 2 relays NO, 10-30VDC
Out of stock
139.70 €

IM1-22EX-R/24VDC is a 2-channel TURCK isolating switching amplifier with intrinsically safe input circuits and two relay outputs, each with one NO contact. Six front switches set the output mode (NO/NC) and switch wire-break and short-circuit monitoring on or off separately for each channel.

  • Channels: 2 inputs for NAMUR sensors (EN 60947-5-6) or potential-free contacts
  • Outputs: 2 relays, 1 NO each, 30 V DC / 250 V AC, ≤2 A, ≤500 VA / 60 W
  • Supply: 10...30 V DC (24 V DC nominal)
  • Housing: polycarbonate/ABS, 104 x 18 x 110 mm, DIN rail (NS35) or panel mounting
  • Connection: screw terminals, 1 x 2.5 mm² / 2 x 1.5 mm²
  • Environment: IP20, -25...+60 °C

Used to pass NAMUR sensor or contact signals from a hazardous area to a relay input in the control cabinet. With monitoring switched on, an input fault turns the channel LED red and the output relay drops out. Mechanical contacts need either monitoring switched off or the resistor wiring shown in the datasheet.

Approvals: ATEX, CFMUS, TR CU.

Relays and converters
Isolating transducer IM33-22EX-HI/24VDC
Out of stock
390.20 €
ATEX, IECEx, UL, CFMUS, TR CU, CCOE, Kosha; Installation in zone 2

Input circuits: 0/4…20 mA
Output circuits: 0/4…20 mA
HMI
Plug-in module TX-CAN, CANopen manager, 9-pin SUB-D male
Out of stock
203.10 €

TX-CAN is a plug-in module for TURCK TX700 HMI/PLC devices that works as a CANopen manager (master) in CODESYS. It supports CAN 2.0A and 2.0B and is galvanically isolated.

  • Interface: CANopen manager/master, CAN 2.0A/2.0B, 10 kbps...1 Mbps
  • Connector: 1 x 9-pin SUB-D, male; external bus termination
  • Configuration: transmission rate and addresses 1...127 set in CODESYS
  • Supply: from the HMI
  • Housing: metal, 41.2 x 90.3 x 23.8 mm
  • Environment: IP20, -20...+60 °C, 5...85 % RH non-condensing

Fits the expansion slots of TX700 HMI/PLC devices and the TX700S gateway; powered from the HMI, no separate supply. The bus terminating resistor is not built in and has to be fitted externally.

Approvals: CE, cULus, Class I Div. 2, DNV-GL.

Relays and converters
Frequency transducer IM12-FI01-2SF-2I-C0/24VDC, 2-channel, 0/4-20mA, 10-30VDC, SIL2
Out of stock
326.90 €

IM12-FI01-2SF-2I-C0/24VDC is a 2-channel TURCK frequency transducer and pulse counter that transfers frequency signals up to 20 kHz with galvanic isolation and converts them to 0/4...20 mA. It is parameterised from a PC via FDT and IODD.

  • Channels: 2 frequency inputs for NAMUR sensors (EN 60947-5-6) or contacts, 0.0006...1,200,000 rpm
  • Outputs: 2 x 0/4...20 mA, source or sink (15...28 V), load ≤0.8 kΩ
  • Configuration: PC via FDT and IODD; inputs assignable as E1, E2, E1-E2 or E2-E1
  • Supply: 10...30 V DC, ≤3 W
  • Housing: polycarbonate/ABS, 120 x 12.5 x 117 mm, DIN rail (NS35), removable screw terminals
  • Environment: IP20, -25...+70 °C

Used for speed monitoring of shafts and conveyors where the pulse sensor sits in a hazardous area. Wire break and short circuit on the input are monitored; the fault current can be set to < 3.5 mA or > 21.5 mA. A PC connection is needed for parameterisation.

Approvals: ATEX, cULus; for use in ATEX Zone 2. SIL 2.

Displays
Touch display TX707-P3CV01, 7", CODESYS V3 PLC, IP66 front
Out of stock
1,271.00 €

TX707-P3CV01 is a 7" touch display from the TURCK TX700 series with a built-in CODESYS V3 PLC, TARGET and WEB VISU visualisation. The PLC program and the screens are built in CODESYS V3 and loaded into the device over Ethernet.

  • Display: 7" TFT, 800 x 480 (WVGA), 16:9, 16M colours, 500 cd/m², capacitive glass front, dimmable to 0 %
  • Communication: 3 x RJ45 Ethernet 10/100 Mbit, 1 x RS232/RS485/RS422, 2 x USB host (v2.0, max. 500 mA), SD card slot
  • Expansion: 2 slots for up to 4 plug-in modules (I/O, CANopen, PROFIBUS DP, RS485, RS232, LTE/Wi-Fi)
  • PLC: CODESYS V3.5.12.10, IEC 61131-3 (IL, LD, FBD, SFC, ST), 20000 kB program memory, 63 kB retain memory; ARM Cortex A9, Dual core 800 MHz, 1024 MB RAM, 4 GB Flash, battery-backed clock
  • Supply: 24 VDC (10...32 VDC), max. 0.7 A
  • Housing: metal, front 187 x 147 x 47 mm, cut-out 176 x 136 mm, mounting depth 29+5 mm
  • Environment: IP66 front, IP20 rear, NEMA 12/4X; -20...+60 °C, 5...85 % RH non-condensing

Built into a cabinet door or control desk. Mounting brackets and the power connector come in the 7" TX700 mounting kit, available as an accessory; I/O and fieldbus modules plug into the expansion slots and are ordered separately.

Approvals: ATEX, IECEx, Haz. Loc. Class I, Division 2, Groups A, B, C and D.

Relays and converters
Isolating switching amplifier IM12-22EX-R, 2-channel, 2 relays NO, 20-125VDC/20-250VAC
Out of stock
149.70 €

IM12-22EX-R is a 2-channel TURCK isolating switching amplifier with intrinsically safe input circuits and two relay outputs, each with one NO contact. Front switches set the output mode (NO/NC) and signal multiplexing, where channel 1 drives both outputs.

  • Channels: 2 inputs for NAMUR sensors (EN 60947-5-6) or potential-free contacts
  • Outputs: 2 relays, 1 NO each, 30 V DC / 250 V AC, ≤2 A, ≤500 VA / 60 W
  • Supply: 20...125 V DC / 20...250 V AC (40...70 Hz)
  • Housing: polycarbonate/ABS, 104 x 18 x 110 mm, DIN rail (NS35) or panel mounting
  • Connection: screw terminals, 1 x 2.5 mm² / 2 x 1.5 mm²
  • Environment: IP20, -25...+70 °C

Used to pass NAMUR sensor or potential-free contact signals from a hazardous area to a relay input in the control cabinet. A green Pwr LED shows readiness and a yellow LED shows the output switching state.

Approvals: ATEX, IECEx, cUL, cFM, CSA, TR CU; for use in Zone 2.

Relays and converters
Isolating switching amplifier IM12-DI01-2S-2T-0/24VDC, 2-channel, 2 transistor outputs, 10-30VDC, SIL2
Out of stock
135.90 €

IM12-DI01-2S-2T-0/24VDC is a 2-channel TURCK isolating switching amplifier in a 12.5 mm housing with two potential-free transistor outputs up to 10 kHz. It runs either as two separate channels or with channel 1 doubled onto both outputs.

  • Channels: 2 inputs for NAMUR sensors (EN 60947-5-6) or potential-free contacts
  • Outputs: 2 potential-free, short-circuit-proof transistors, ≤30 V DC, 0.1 A, ≤10 kHz
  • Supply: 10...30 V DC, ≤0.8 W
  • Housing: polycarbonate/ABS, 120 x 12.5 x 117 mm, DIN rail (NS35)
  • Connection: removable screw terminals, 0.2...2.5 mm²
  • Environment: IP20, -25...+70 °C

DIP switches on the front set the output mode, input circuit monitoring and the operating mode. An input fault makes the red LED flash according to NE44 and blocks the transistor of that channel. Mechanical contacts need either monitoring switched off or the resistor wiring shown in the datasheet.

Approvals: ATEX, cULus; for use in ATEX Zone 2. Usable in safety circuits up to SIL 2 (IEC 61508).

Relays and converters
Temperature measuring amplifier IM12-TI02-2TCURTDR-2I-C0/24VDC, TC/RTD, 2-channel, 0/4-20mA, SIL2
Out of stock
321.20 €

IM12-TI02-2TCURTDR-2I-C0/24VDC is a 2-channel TURCK temperature measuring amplifier for thermocouples, RTDs, resistors and mV signals. It converts the inputs to galvanically isolated 0/4...20 mA outputs; cold junction compensation can be internal, external or a fixed value.

  • Inputs: 2 x thermocouple (IEC 60584, DIN 43710), -150...+150 mV, RTD (IEC 60751, DIN 43760) or 0...5 kΩ, 2- or 3-wire
  • Outputs: 2 x 0/4...20 mA, source or sink (15...28 V); inputs assignable as E1, E2, E1-E2 or E2-E1
  • Configuration: PC via FDT and IODD
  • Supply: 10...30 V DC, ≤2.7 W
  • Housing: polycarbonate/ABS, 120 x 12.5 x 117 mm, DIN rail (NS35), removable screw terminals
  • Environment: IP20, -25...+70 °C

Used where a mix of thermocouples and RTDs from a hazardous area has to reach the control system as current signals. With a 3-wire RTD connection, the lead resistances must be equal. Input faults are indicated according to NE44, and a PC connection is needed for parameterisation.

Approvals: ATEX, cULus; for use in ATEX Zone 2. SIL 2.

Displays
Touch display TXF705-00VPST, 5", TX VisuPro runtime, PoE, IP67
Out of stock
684.00 €

TXF705-00VPST is a 5" touch display from the TURCK TXF700 series with TX VisuPro runtime, a metal housing sealed to IP67 all round and a capacitive multi-touch glass front. Power and data come over one PoE Ethernet cable, so it can be mounted on a machine, pipe or wall outside the cabinet.

  • Display: 5" TFT, 800 x 480 (WVGA), 16:9, 16M colours, 300 cd/m², capacitive multi-touch with gesture control, dimmable to 0 %
  • Communication: 1 x RJ45 PoE Ethernet 10/100 Mbit, 1 x USB host (special cable required)
  • Built in: temperature sensor, 3-axis accelerometer, front RGB LED, beeper
  • Software: TX VisuPro runtime; ARM Cortex A9, dual core 800 MHz, 1 GB RAM, 4 GB Flash, battery-backed clock
  • Supply: PoE IEEE 802.3af, ≤ 6 W
  • Housing: metal, 148.3 x 105.1 x 16.5 mm, mounting depth 17 mm
  • Environment: IP67, NEMA 1/12/4X; -20...+55 °C, 5...85 % RH non-condensing

The PoE connection is an M22 socket on the device: a TXF M22-to-RJ45 PoE cable and a PoE switch or injector are needed. Pipe, wall, VESA, gooseneck and tabletop mounts are available as accessories.

Approvals: Haz. Loc. Class I, Division 2, Groups A, B, C and D.

HMI
Touch display TX707FB-P3CV01, 7", CODESYS V3 PLC, IP69 front, food & beverage
Out of stock
1,861.00 €

TX707FB-P3CV01 is a 7" touch display from the TURCK TX700 series with a built-in CODESYS V3 PLC, TARGET and WEB VISU visualisation. The FB version for the food industry has a stainless steel AISI 316L frame, a food-grade seal and an IP69 front that withstands high-pressure water up to 80 °C, acids and chemicals.

  • Display: 7" TFT, 800 x 480 (WVGA), 16:9, 16M colours, 500 cd/m², capacitive glass front with polyester coating, dimmable to 0 %
  • Communication: 3 x RJ45 Ethernet 10/100 Mbit, 1 x RS232/RS485/RS422, 2 x USB host (v2.0, max. 500 mA), SD card slot
  • Expansion: 2 slots for up to 4 plug-in modules (I/O, CANopen, PROFIBUS DP, RS485, RS232, LTE/Wi-Fi)
  • PLC: CODESYS V3.5.12.10, IEC 61131-3 (IL, LD, FBD, SFC, ST), 20000 kB program memory, 63 kB retain memory; ARM Cortex A9, Dual core 800 MHz, 1024 MB RAM, 4 GB Flash, battery-backed clock
  • Supply: 24 VDC (10...32 VDC), max. 0.7 A
  • Housing: die-cast aluminium, stainless steel AISI 316L frame, polyester front foil, front 217 x 177 x 45 mm, cut-out 176 x 136 mm, mounting depth 45+10 mm
  • Environment: IP69 front, IP20 rear, NEMA 12/4X; -20...+60 °C, 5...85 % RH non-condensing

Intended for operator stations in food and beverage production. Built into a cabinet door or control desk. Mounting brackets and the power connector come in the 7" TX700 mounting kit, available as an accessory; I/O and fieldbus modules plug into the expansion slots and are ordered separately.

HMI
Plug-in module TX-IO-XX03, 20 DI, 12 DO, 4 AI, 4 AO
Out of stock
701.00 €

TX-IO-XX03 is a plug-in I/O module for TURCK TX700 HMI/PLC devices with 20 digital inputs, 12 digital outputs, four universal analogue inputs for voltage, current, RTD and thermocouples, and four analogue outputs for voltage or current.

  • Digital inputs: 20 x 24 VDC, PNP, input delay 0.05 ms (S inputs) / 0.0002 ms (E inputs)
  • Digital outputs: 12 x 24 VDC, PNP, 0.5 A per channel, simultaneity factor 0.23, short-circuit protected
  • Analogue inputs: 4, 12 bit; ±100 mV...±10 V, 0...10 V, 0/4...20 mA, RTD -100...+850 °C (2-, 3-, 4-wire), thermocouple E, J, K, R, S, T; basic error 0.1 % at 25 °C
  • Analogue outputs: 4, 12 bit; ±10 V (load > 1 kΩ) or 0...20 mA (load < 470 Ω)
  • Supply: 24 VDC (12...30 VDC), I/O optically isolated at 1500 V rms
  • Housing: metal, 125.2 x 89.3 x 33.7 mm; pluggable 10-pin spring terminal strips, 3.5 mm pitch
  • Environment: IP20, 0...+50 °C, 5...85 % RH non-condensing

Fits the expansion slots of TX700 HMI/PLC devices and the TX700S gateway. The I/O are handled by the CODESYS PLC in the HMI. Thermocouple cold junction compensation is external, through a Pt100 on the compensation input. On the 5" TX705 and the TX700S gateway the module needs the TX-EXTEND adapter.

Approvals: CE, cULus, Class I Div. 2, DNV-GL.

HMI
Plug-in module TX-IO-DX06, 8 DI, 6 DO, 1 relay NO
Out of stock
233.10 €

TX-IO-DX06 is a plug-in I/O module for TURCK TX700 HMI/PLC devices with eight PNP digital inputs, six PNP digital outputs and one relay output, optically isolated at 1500 V rms.

  • Inputs: 8 x DI, 24 VDC, PNP, input delay < 0.05 ms
  • Outputs: 6 x DO, 24 VDC, PNP, 0.5 A per channel, simultaneity factor 0.46, short-circuit protected; 1 x relay, NO contact
  • Supply: 24 VDC (12...30 VDC), actuator supply fed externally
  • Connection: 2 pluggable 10-pin spring terminal strips, 3.5 mm pitch (Weidmüller Omnimate BLZF 3.5/180F); supply on a cage-clamp strip
  • Housing: metal, 41.2 x 89.3 x 33.7 mm
  • Environment: IP20, 0...+50 °C, 5...85 % RH non-condensing

Fits the expansion slots of TX700 HMI/PLC devices and the TX700S gateway. The I/O are handled by the CODESYS PLC in the HMI.

Approvals: CE, cULus, DNV GL.

PLC and FLC
IoT gateway TX700S-P3WV01, CODESYS V3 PLC, WEB VISU, 2x Ethernet
Out of stock
611.00 €

TX700S-P3WV01 is a TURCK TX700 series IoT gateway without a display: a single-core CODESYS V3 PLC with WEB VISU, so the visualisation is opened in a web browser. It has two separate Ethernet ports and one expansion slot for plug-in modules.

  • Communication: 2 x RJ45 Ethernet 10/100 Mbit (separate), 1 x RS232/RS485/RS422, 1 x USB host, SD card slot
  • Expansion: 1 slot for up to 2 plug-in modules (I/O, CANopen, PROFIBUS DP, RS485, RS232, LTE/Wi-Fi)
  • PLC: CODESYS V3.5.12.10, IEC 61131-3 (IL, LD, FBD, SFC, ST), 20000 kB program memory, 63 kB retain memory, programmed over Ethernet
  • Controller: ARM Cortex A8, 1 GHz, 512 MB RAM, 4 GB Flash, battery-backed clock
  • Supply: 24 VDC (10...32 VDC), max. 0.35 A
  • Housing: 134 x 45 x 102 mm
  • Environment: IP20, -20...+60 °C, 5...85 % RH non-condensing

The TX-PSC power connector and plug-in modules are available as accessories; the TX-IO-XX03 module needs the TX-EXTEND adapter in this housing.

HMI
Plug-in module TX-RS485, RS485/RS422, 9-pin SUB-D female
Out of stock
203.10 €

TX-RS485 is a plug-in module for TURCK TX700 HMI/PLC devices that adds a galvanically isolated RS485/RS422 interface on a 9-pin SUB-D female connector.

  • Interface: RS485/RS422, 9.6...115.2 kbps, galvanically isolated
  • Connector: 1 x 9-pin SUB-D, female
  • Supply: from the HMI
  • Housing: metal, 41.2 x 90.3 x 23.8 mm
  • Environment: IP20, -20...+60 °C, 5...85 % RH non-condensing

Fits the expansion slots of TX700 HMI/PLC devices and the TX700S gateway; powered from the HMI, no separate supply. The module has a plug-in extension port.

Approvals: CE.

Relays and converters
Temperature measuring amplifier IM34-12EX-RI
Out of stock
371.60 €
ATEX, IECEx, CFMUS, UL, TR CU, INMETRO, CCOE, NEPSI, KOSHA; Installation in zone 2
HMI
Touch display TX107-00VPST, 7", TX VisuPro runtime, resistive, IP66 front
Out of stock
587.00 €

TX107-00VPST is a 7" touch display from the TURCK TX100 series with TX VisuPro runtime, a plastic housing and a resistive touchscreen behind a plastic front film. It works as an operator panel only and has no built-in PLC.

  • Display: 7" TFT, 800 x 480 (WVGA), 16:9, 64K colours, 200 cd/m², resistive, dimmable
  • Communication: 1 x RJ45 Ethernet 10/100 Mbit, 1 x RS232/RS485/RS422, 1 x USB host
  • Software: TX VisuPro runtime; ARM Cortex A8, 1 GHz, 512 MB RAM, 4 GB Flash
  • Supply: 24 VDC (10...32 VDC), max. 0.3 A
  • Housing: plastic, front 187 x 147 x 34 mm, cut-out 176 x 136 mm, mounting depth 29+5 mm
  • Environment: IP66 front, IP20 rear, NEMA 2/4X; 0...+50 °C, 5...85 % RH non-condensing

Built into a cabinet door or control desk. Mounting brackets and the power connector come in the TX100 mounting kit, available as an accessory. There are no expansion slots.

Approvals: Haz. Loc. Class I, Division 2, Groups A, B, C and D.

Relays and converters
Temperature measuring amplifier IM12-TI01-2RTDR-2I-C0/24VDC, RTD, 2-channel, 0/4-20mA, SIL2
In stock: 2 pcs
290.40 €

IM12-TI01-2RTDR-2I-C0/24VDC is a 2-channel TURCK temperature measuring amplifier for resistance thermometers. It converts two RTD or resistance signals to galvanically isolated 0/4...20 mA outputs and also outputs the difference of the two inputs.

  • Inputs: 2 x RTD (Pt50, Pt100, Pt500, Pt1000, Ni50, Ni100, Ni500 and others) or 0...5 kΩ, 2-, 3- or 4-wire
  • Outputs: 2 x 0/4...20 mA, source or sink (15...28 V); inputs assignable as E1, E2, E1-E2 or E2-E1
  • Configuration: PC via FDT and IODD
  • Supply: 10...30 V DC, ≤2.7 W
  • Housing: polycarbonate/ABS, 120 x 12.5 x 117 mm, DIN rail (NS35), removable screw terminals
  • Environment: IP20, -25...+70 °C

Used to bring Pt100 and similar sensors from a hazardous area into a control system as a standard current signal. Wire break and short circuit are indicated by a flashing red LED according to NE44, and the fault current can be set to < 3.5 mA or > 21.5 mA. A PC connection is needed for parameterisation.

Approvals: ATEX, cULus; for use in ATEX Zone 2. SIL 2.

Relays and converters
Temperature measuring amplifier IM34-11EX-I
Out of stock
352.90 €
ATEX, IECEx, CFMUS, UL, TR CU, INMETRO, CCOE, NEPSI, KOSHA; Installation in zone 2
HMI
Touch display TX110-00VPST, 10.1", TX VisuPro runtime, resistive, IP66 front
Out of stock
906.00 €

TX110-00VPST is a 10.1" touch display from the TURCK TX100 series with TX VisuPro runtime, a plastic housing and a resistive touchscreen behind a plastic front film. It works as an operator panel only and has no built-in PLC.

  • Display: 10.1" TFT, 1024 x 600 (WVGA), 16:9, 64K colours, 200 cd/m², resistive, dimmable
  • Communication: 1 x RJ45 Ethernet 10/100 Mbit, 1 x RS232/RS485/RS422, 1 x USB host
  • Software: TX VisuPro runtime; ARM Cortex A8, 1 GHz, 512 MB RAM, 4 GB Flash
  • Supply: 24 VDC (10...32 VDC), max. 0.38 A
  • Housing: plastic, front 282 x 197 x 35 mm, cut-out 271 x 186 mm, mounting depth 29+6 mm
  • Environment: IP66 front, IP20 rear, NEMA 2/4X; 0...+50 °C, 5...85 % RH non-condensing

Built into a cabinet door or control desk. Mounting brackets and the power connector come in the TX100 mounting kit, available as an accessory. There are no expansion slots.

Approvals: Haz. Loc. Class I, Division 2, Groups A, B, C and D.

HMI
Touch display TX710-P3CV01, 10.1", CODESYS V3 PLC, IP66 front
Out of stock
1,945.00 €

TX710-P3CV01 is a 10.1" touch display from the TURCK TX700 series with a built-in CODESYS V3 PLC, TARGET and WEB VISU visualisation. The PLC program and the screens are built in CODESYS V3 and loaded into the device over Ethernet.

  • Display: 10.1" TFT, 1280 x 800 (WXGA), 16:9, 16M colours, 500 cd/m², capacitive glass front, dimmable to 0 %
  • Communication: 3 x RJ45 Ethernet 10/100 Mbit, 1 x RS232/RS485/RS422, 2 x USB host (v2.0, max. 500 mA), SD card slot
  • Expansion: 2 slots for up to 4 plug-in modules (I/O, CANopen, PROFIBUS DP, RS485, RS232, LTE/Wi-Fi)
  • PLC: CODESYS V3.5.12.10, IEC 61131-3 (IL, LD, FBD, SFC, ST), 20000 kB program memory, 63 kB retain memory; ARM Cortex A9, Dual core 800 MHz, 1024 MB RAM, 4 GB Flash, battery-backed clock
  • Supply: 24 VDC (10...32 VDC), max. 1.0 A
  • Housing: metal, front 282 x 197 x 56 mm, cut-out 271 x 186 mm, mounting depth 56+8 mm
  • Environment: IP66 front, IP20 rear, NEMA 12/4X; -20...+60 °C, 5...85 % RH non-condensing

Built into a cabinet door or control desk. Mounting brackets and the power connector come in the 10.1" TX700 mounting kit, available as an accessory; I/O and fieldbus modules plug into the expansion slots and are ordered separately.

Relays and converters
Isolating switching amplifier IM1-22EX-R, 2-channel, 2 relays NO, 20-125VDC/20-250VAC, SIL2
Out of stock
146.50 €

IM1-22EX-R is a 2-channel TURCK isolating switching amplifier with intrinsically safe input circuits and two relay outputs, each with one NO contact. Six front switches set the output mode (NO/NC) and switch wire-break and short-circuit monitoring on or off separately for each channel.

  • Channels: 2 inputs for NAMUR sensors (EN 60947-5-6) or potential-free contacts
  • Outputs: 2 relays, 1 NO each, 30 V DC / 250 V AC, ≤2 A, ≤500 VA / 60 W
  • Supply: 20...125 V DC / 20...250 V AC (40...70 Hz)
  • Housing: polycarbonate/ABS, 104 x 18 x 110 mm, DIN rail (NS35) or panel mounting
  • Connection: screw terminals, 1 x 2.5 mm² / 2 x 1.5 mm²
  • Environment: IP20, -25...+70 °C

Used to pass NAMUR sensor or contact signals from a hazardous area to a relay input in the control cabinet. With monitoring switched on, an input fault turns the channel LED red and the output relay drops out. Mechanical contacts need either monitoring switched off or the resistor wiring shown in the datasheet.

Approvals: ATEX, IECEx, UL, CFMUS, CSA, TR CU; for use in Zone 2. SIL 2 according to exida FMEDA.

Relays and converters
Isolating switching amplifier IM12-22EX-R/24VDC, 2-channel, 2 relays NO, 10-30VDC
Out of stock
139.20 €

IM12-22EX-R/24VDC is a 2-channel TURCK isolating switching amplifier with intrinsically safe input circuits and two relay outputs, each with one NO contact. Front switches set the output mode (NO/NC) and signal multiplexing, where channel 1 drives both outputs.

  • Channels: 2 inputs for NAMUR sensors (EN 60947-5-6) or potential-free contacts
  • Outputs: 2 relays, 1 NO each, 30 V DC / 250 V AC, ≤2 A, ≤500 VA / 60 W
  • Supply: 10...30 V DC (24 V DC nominal)
  • Housing: polycarbonate/ABS, 104 x 18 x 110 mm, DIN rail (NS35) or panel mounting
  • Connection: screw terminals, 1 x 2.5 mm² / 2 x 1.5 mm²
  • Environment: IP20, -25...+60 °C

Used to pass NAMUR sensor or potential-free contact signals from a hazardous area to a relay input in the control cabinet. A green Pwr LED shows readiness and a yellow LED shows the output switching state.

Approvals: ATEX, CFMUS, TR CU.

Displays
Touch display TX715FB-P3CV01, 7", CODESYS V3 PLC, IP69 front, food & beverage
Out of stock
3,078.00 €

TX715FB-P3CV01 is a 7" touch display from the TURCK TX700 series with a built-in CODESYS V3 PLC, TARGET and WEB VISU visualisation. The FB version for the food industry has a stainless steel AISI 316L frame, a food-grade seal and an IP69 front that withstands high-pressure water up to 80 °C, acids and chemicals.

  • Display: 7" TFT, 1366 x 768 (HD), 16:9, 16M colours, 400 cd/m², capacitive glass front with polyester coating, dimmable to 0 %
  • Communication: 3 x RJ45 Ethernet 10/100 Mbit, 1 x RS232/RS485/RS422, 2 x USB host (v2.0, max. 500 mA), SD card slot
  • Expansion: 2 slots for up to 4 plug-in modules (I/O, CANopen, PROFIBUS DP, RS485, RS232, LTE/Wi-Fi)
  • PLC: CODESYS V3.5.12.10, IEC 61131-3 (IL, LD, FBD, SFC, ST), 20000 kB program memory, 63 kB retain memory; ARM Cortex A9, Quad core 800 MHz, 2048 MB RAM, 8 GB Flash, battery-backed clock
  • Supply: 24 VDC (10...32 VDC), max. 1.2 A
  • Housing: die-cast aluminium, stainless steel AISI 316L frame, polyester front foil, mounting depth 56+8 mm
  • Environment: IP69 front, IP20 rear, NEMA 12/4X; -20...+60 °C, 5...85 % RH non-condensing

Intended for operator stations in food and beverage production. Built into a cabinet door or control desk. Mounting brackets and the power connector come in the 7" TX700 mounting kit, available as an accessory; I/O and fieldbus modules plug into the expansion slots and are ordered separately.

Relays and converters
Isolating transducer HART transparent, IMXK12-AI01-1I-1I-H0/24VDC/CC
In stock: 1 pcs
255.50 €

1-channel

    • Input circuits monitored for wire break and short circuit
    • Complete galvanic isolation
    • HART transparent
    • Removable cage clamp terminals
    • ATEX, IECEx, cULus
    • Use in zone 2
    • SIL 2
Relays and converters
Isolating switching amplifier IM12-DI01-2S-2T-PR/24VDC, 2-channel, 2 transistor outputs, 10-30VDC, Power bridge, SIL2
Out of stock
154.00 €

IM12-DI01-2S-2T-PR/24VDC is a 2-channel TURCK isolating switching amplifier in a 12.5 mm housing with two potential-free transistor outputs up to 10 kHz. It can be powered through a Power bridge, which also carries a collective fault signal; the connector for the bridge is included.

  • Channels: 2 inputs for NAMUR sensors (EN 60947-5-6) or potential-free contacts
  • Outputs: 2 potential-free, short-circuit-proof transistors, ≤30 V DC, 0.1 A, ≤10 kHz
  • Supply: 10...30 V DC via terminals or Power bridge, ≤0.8 W
  • Housing: polycarbonate/ABS, 120 x 12.5 x 117 mm, DIN rail (NS35)
  • Connection: removable screw terminals, 0.2...2.5 mm²
  • Environment: IP20, -25...+70 °C

DIP switches on the front set the output mode, input circuit monitoring and the operating mode. An input fault makes the red LED flash according to NE44 and blocks the transistor of that channel. Mechanical contacts need either monitoring switched off or the resistor wiring shown in the datasheet.

Approvals: ATEX, cULus; for use in ATEX Zone 2. Usable in safety circuits up to SIL 2 (IEC 61508).

Relays and converters
Isolating transducer IM12-AI01-1I-2IU-HPR/24VDC/CC, HART, 4-20mA splitter, Power bridge, SIL2
Out of stock
312.30 €

IM12-AI01-1I-2IU-HPR/24VDC/CC is a 1-channel TURCK isolating transducer for HART 2-wire transmitters. The 4...20 mA input is passed 1:1 to two isolated outputs (splitter), and HART communication runs bidirectionally through output O1.

  • Channels: 1 input, 4...20 mA, transmitter supply 17 V / 20 mA
  • Outputs: 2 x 4...20 mA (source or sink) or 1...5 V; HART on O1 only
  • Accuracy: ≤0.05 % of full scale
  • Supply: 10...30 V DC via terminals or Power bridge, ≤3.8 W
  • Housing: polycarbonate/ABS, 120 x 12.5 x 128 mm, DIN rail (NS35), removable spring-type terminals
  • Environment: IP20, -25...+70 °C

Used where one transmitter signal from a hazardous area is needed by two systems, for example a control system and a separate safety system. Wire break (< 3.5 mA) and short circuit (> 22 mA) are passed to the outputs as < 3.5 mA or < 0.875 V. The Power bridge also carries a collective fault signal; its connector is included.

Approvals: ATEX, cULus; for use in ATEX Zone 2. SIL 2.

Relays and converters
Isolating switching amplifier IM12-DI03-1S-2T-S/24VDC/CC, 1-channel, 2 transistor outputs, 10-30VDC, SIL2
Out of stock
123.90 €

IM12-DI03-1S-2T-S/24VDC/CC is a 1-channel TURCK isolating switching amplifier in a 12.5 mm housing with two potential-free transistor outputs up to 10 kHz. The second output works either as a copy of the signal or as an alarm output for input faults.

  • Channels: 1 input for NAMUR sensors (EN 60947-5-6) or potential-free contacts
  • Outputs: 2 potential-free, short-circuit-proof transistors, ≤30 V DC, 0.1 A, ≤10 kHz
  • Supply: 10...30 V DC, ≤1.03 W typical dissipation
  • Housing: polycarbonate/ABS, 120 x 12.5 x 128 mm, DIN rail (NS35)
  • Connection: removable spring-type terminals, 0.2...2.5 mm²
  • Environment: IP20, -25...+70 °C

DIP switches on the front set the output mode, input circuit monitoring and the operating mode. An input fault makes the red LED flash according to NE44 and blocks the transistor of that channel. Mechanical contacts need either monitoring switched off or the resistor wiring shown in the datasheet.

Approvals: ATEX, cULus; for use in ATEX Zone 2. Usable in safety circuits up to SIL 2 (IEC 61508).

Showing 49 of 49 results